Connetion diagrams 6.12T
6.12.2.2 HS0 triple phase V2/V3 (BM340X-L3XXX-XXXXXXX-O)
Connector Quantity Usage Type
X26 2 dig./anal. IO COMBICON FK-MC 0,5/12-ST-2,5
X102 1 safety relay COMBICON MC 1.5/4-ST-3.5
X100 1 24V-supply COMBICON MC 1,5/6-ST-3,5
X202 1 power input COMBICON GMSTB 2,5/4-ST-7,62
X102-4, M24V_R
X102-3, + 24V_R
X102-2, KS_S
X102-1, KS_P
X100-6, -24V
X100-5, -24V
X100-4, B_EIN
X100-3, N_EIN
X100-2, + 24V
X100-1, + 24V
X202-4, 1W1
X202-3, 1V1
X202-2, 1U1
X202-1, PE
Figure 6.22: Connections on top at HS0 (triple phase supply) for type key V2 a c c. to HS1
Instrution Manual
b maXX
®
BM3400
81
Doument No.: 5.07013.03 from 206