Marking of the device - type key
Compact manual b maXX
®
BM4400, BM4600, BM4700
Document no.: 5.06014.02 Baumüller Nürnberg GmbH
10
of 94
3.1
The type key has the form: BM4XXX - XXX - XXXXX[Ryy] - XX. Directly behind the type
key is the design code (-XXXX - X - XXX - XXX). The design code contains information,
which only is important to Baumüller Nürnberg GmbH.
That’s why in the following table only the type key is explained.
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Device generation
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Type
4: Vector controller with and without encoder feedback (closed loop / open loop)
5: for M-controller oder V-controller developed devices,
see manual 5.05022
6: Vector controller like 4, but optimzed for max. peak current
7: Vector controller like 4, but optimzed for max. nominal current
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Size of cabinet
1 to 7 (from cabinet size 1 there are two different wide versions)
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Current grading (output rated current)
0 to 6 (current value is dependent on the cabinet size), see appendix D
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Cooling type
S: air-cooled with air supply and with air outlet in the control cabinet
A: air-cooled with air supply and with air outlet outside the control cabinet
Z: water-cooled with water cooler in the control cabinet
F: water-cooled with water cooler outside the control cabinet
C: (cold plate) cooling via mounting wall of the control cabinet
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Mains type
T: TN- or TT-mains
I: IT-mains and ’grounded delta’
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Safety relay
0: no module
1: Module with one relay and high power current contacts
2: Module with two relays and high power current contacts
3: Module with one relay and low current contacts
4: Module with two relays and low current contacts
5: Module with one relay and all current contacts
6: Module with two relays and all current contacts
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Hardware type/power unit type
0: Rectifier and inverter with chopper resistor transistor U
DC
= 540 V
1: Rectifier and inverter with chopper resistor transistor
U
Mains
=230 V ± 10 %, U
DC
=310 V
2: Power module (only output sided inverter). Operation as power module,
U
DC
= 540 V
3: Rectifier and inverter with chopper resistor transistor U
DC
= 540 V
short packaging for BM465X, BM466X, BM475X und BM476X
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Hardware type/controller unit versions
1: Module in slots A to H pluggable
2: Modules in slots A to M pluggable
BM4XXX - XXX - XXXXX[Ryy] - [XXX] - XX Hardware type (internal information via Baumüller Nürnberg
GmbH.
0XX: Controller without 7-segment display (RS 485 interface)
1XX: Controller without 7-segment display (RS 485 interface)
2XX :Controller with 7-segment display (RS 485 interface)
3XX :Controller with 7-segment display (Ethernet interface))