Commissioning
Compact manual b maXX
®
BM4400, BM4600, BM4700
Document no.: 5.06014.02
55
of 94
6
42Check if the measured value meets the expected value (6)
(at Baumüller motors: resolver: 330°, sine-cosine 240° ± 5°).
43Inactivate the pulse enable and quickstop clearance.
With this activity all parameterization workings for an exemplary commissioning are com-
pleted. You can now convince yourself from the proper functions, by letting the motor ro-
tate shortly.
First rotating of
the motor.
44Go back to the ProDrive Navigation.
45Double-click on: ’setpoint generators’.
46Click on: ’ramp function generator’.