Operation
Compact manual b maXX
®
BM4400, BM4600, BM4700
Document no.: 5.06014.02
61
of 94
7
7.3.2 Current limit (H3)
The third LED (H-3) indicates whether the current limit has been reached.
7.3.3 Error (H4)
7.3.4 Display
The 7-segment-display in normal operation shows the operation status. In case of error
the error number is shown.
The single drive statuses are specified in chapter device management in parameter man-
ual 5.03039.
red: adjusted current limit of the controller has been reached.
h Application is adapted or ’no reaction’.
LED doesn’t light up: the internal monitoring have not found an error.
Red, continuously: Error.
h Remove the error with help of the operating program WinBASS II / ProDrive. Fu
r-
ther information is to be found in ZError detection and troubleshootingfrom pag
e
63.
red, flashing: Warning.
h Warnings you are able to see in the drive manager of the operating program Wi
n-
BASS II / ProDrive. Warnings do not affect operation of the device. Further info
r-
Display Status Meaning
0 Not ready-to-start Initialization phase, pulses inhibited.
1 Inhibit start Pulses inhibited, initialization completed error-free.
2 Ready-to-start Pulses inhibited
3 Switched on Pulses for field generation at asynchronous machines enabled,
no torque generation yet.
4 Operation enabled Pulses enabled, drive function enabled
5 Inhibit operation active Pulses enabled, braking procedure active
6 Shutdown active Pulses enabled, braking procedure active
7 Quickstop active Pulses enabled, braking procedure active
E Error reaction active Pulses enabled, braking procedure active
F Error Pulses inhibited, error status
In the display the error number is shown.