Troubleshooting
Compact manual b maXX
®
BM4400, BM4600, BM4700
Document no.: 5.06014.02 Baumüller Nürnberg GmbH
82
of 94
8.2
Error Function module A to E P0240 to P0244
Level 3 error
no.
Meaning Reaction Troubleshooting
0 Reserved error
1 Module not detected adjustable Check if the correct module is located at the correct slot
2 Module not permitted at this
position
adjustable Check if the correct module is located at the correct slot
3 24 V missing or output short-
circuited
adjustable Check the wiring of the digital outputs
4 Wrong target parameter value
by digital input
adjustable Check the parametrization of the input channel
5 Direct PLC-I/O access for this
module not permitted
adjustable Do not select the module
6 Reserved error
7 Module not allowed in control-
ler
IS Remove the module
8 to 15 Reserved error