Current consumption of encoder modules
Instruction Handbook b maXX (BM4-F-)ENC-XX (Encoder module)
Document No.: 5.01042.12 Baumüller Nürnberg GmbH
20
of 102
3.2
3.2 Current consumption of encoder modules
Voltage -15 V +5,0 V +15 V
Module type
BM4-F-ENC-01 24 mA 32 mA
BM4-F-ENC-11 23 mA 34 mA
BM4-F-ENC-21 24 mA 32 mA
BM4-F-ENC-02 24 mA 16 mA 13 mA
BM4-F-ENC-12 24 mA 16 mA 13 mA
BM4-F-ENC-03 54 mA 9 mA
BM4-F-ENC-04 50 mA
BM4-F-ENC-05 60 mA
BM4-F-ENC-06 75 mA
BM4-F-ENC-07 60 mA
BM4-F-ENC-17 75 mA
BM4-F-ENC-27 70 mA
BM4-F-ENC-08 48 mA 32 mA 26 mA