Installation
Instruction Handbook b maXX (BM4-F-)ENC-XX (Encoder module)
Document No.: 5.01042.12
61
of 102
7
Construction guidance connection cable for (BM4-F-)ENC-07
m sine cosine encoder with SSI interface, without encoder supply
Construction guidance:
1 Use the following materials:
m Cable: LiYCY 5 x (2 x 0.14) + 2 x 0.5 mm², Cu braiding with at least 85 % opt. overlap
m Sub-D connector. 15-pole, male
m Suitable encoder plug
2 Connect the cable shield with the cabinet of the circular connector and with the shield
of the Sub-D connector
Figure 11: Connection cable BM4-F-ENC-07
NOTE
The connection cable is not offered by Baumüller Nürnberg GmbH and must be made
by the user.