EasyManua.ls Logo

Baumuller b maxx BM4400 - Homing on Home Switch

Baumuller b maxx BM4400
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
67
of 102
Instruction Handbook b maXX (BM4-F-)ENC-XX (Encoder module)
Document No.: 5.01042.12
8COMMISSIONING/OPERATION
This test-commissioning assures, that the (BM4-F-)ENC-XX has been correctly recog-
nized. Further information relating to commissioning and parameter settings of the encod-
er module can be found in parameter manual b maXX 4000 5.03039.
Assure, that before commissioning the following preconditions are fulfilled:
1 The BM4-F-ENC-XX is correctly mounted (standard controller only).
2 The encoder is correctly mounted at the motor.
The encoder must be suitable for the encoder module, must be approved by Baumüller
Nürnberg GmbH and must be correctly cabled.
3 The switching cabinet is properly closed and all safety devices are put into operation.
4 The b maXX 4000 is ready-for-use.
8.1 Safety notes
Basics
WARNING!
Risk of injury due to improper operation!
Improper operation can lead to severe personal injury or material damage.
Therefore:
m Perform all operational steps according to the details of these instruction hand-
book.
m Before beginning any work, ensure that all coverings and protective devices are
installed and are functioning properly.
m The control cabinet in which the device is installed should be protected against
contact with electrically live parts.
Keep all doors of the control cabinet closed during operation.

Table of Contents