Power input
Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module)
Document No.: 5.01045.08 Baumüller Nürnberg GmbH
20
of 82
3.2
3.2 Power input
*)
: Displayed in ProDrive navigation „Service“
3.3 Input linearity error
Note:
The specifications are related to the LSB of the associated module.
Tolerances of offset and gain can be adjusted within the controller.
3.4 Operation conditions
The operation conditions of the b maXX 4000 5.12008 are valid.
(BM4-F-)AIO-
01 02 03
up to (BM4-F-)AIO-03-00
version C*
)
03
from (BM4-F-)AIO-03-01
version D*
)
04
Voltage
5,0 V 0,2 mA 4 mA 10 mA 5 mA 4 mA
3,3 V - - 160 mA 40 mA -
+15,0 V 27 mA 37 mA 20 mA 23 mA 37 mA
-15,0 V 26 mA 35 mA 19 mA 22 mA 35 mA
8,0 V - - - - -
DNL
min
DNL
typ
DNL
max
INL
min
INL
typ
INL
max
Offset
min
Offset
typ
Offset
max
Gain
min
Gain
typ
Gain
max
AIO-01 0 2 6 0 2 5 0 3 6 0 4 8
AIO-02 0 2 4 0 3 6 0 3 6 0 3 6
AIO-03 0 2 4 0 2 4 0 8 16 0 15 50
AIO-04 0 2 4 0 3 6 0 3 6 0 3 6
Transportation temperature range - 25 °C bis + 70 °C
Transportation climate classification EN 60721-3-2 2 K 3
Storage temperature range - 25 °C bis + 55 °C
Storage climate classification EN 60721-3-1 1 K 4
NOTICE!
Normally, only non-conductive pollution occurs. Any conductive pollution, if for a
short-term or permanently, is forbidden and can cause the destruction of the device.
The customer is responsible for destructions, caused by conductive materials.