Safety
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
Document no.: 5.09013.07
23
of 114
4
4.10 Electric safety
The plug-in module is designed for contamination level 2 in accordance with
DIN EN 61800-5-1. This means that only non-conductive contamination may appear
du
ring operating time. Short-term conductivity from condensation is only permissible if the
module is not in operation.
WARNING!
Risk of injury from conductive contaminants!
No conductive contaminants may ap
pear during operating time.
Therefore:
m Before installing the s
ystem, check that contamination degree 2 is not exceeded,
and ensure so by additional measures, if necessary.
4.10.1 Notice on power supply
WARNING!
Risk of injury from electric current!
Only devices which have a safe disconnection to the 230 volt mains may be
co
nnected to the plug-in module.
The power supply unit for generating the 24 Volt supply must meet the requirements
for PELV in accordance
with EN 60204-1.
4.11 Safety equipment
WARNING!
Live-threatening danger from inoperable safety equipment!
Safety equipment provides a maximum of safety du
ring operation. Even if the safety
equipment may make work processes more complicated, they may not be put out of
operation under any circumstances. Safety is only ensured if the safety equipment is
intact.
Therefore:
m Check to make sure that the safety equipm
ent is functional and installed properly
before beginning work.