Operation and display elements
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
Document no.: 5.09013.07 Baumüller Nürnberg GmbH
54
of 114
8.11
8.11 Operation and display elements
8.11.1 LEDs for indicating the operation statuses
There are two LEDs (LED H1 - green, LED H2 - red) on the front of the Safety
Module (SAF-001-000-xxx) that indicate the current operation status.
m LED H1 (green) - Indicates the trouble-free operation
m LED H2 (red) - Indicates failures or incompatibility
with the converter
H1
H2
S1
X1
SAF-001
LED H1 - green
LED H2 - red
Type plate
Figure 16: LEDs on front of the Safety Module (SAF-001-000-xxx)
The following table lists the possible combinations of the status LEDs and the
corresponding meaning:
LED
H1 (green) H2 (red) Meaning
Off Off No supply voltage.
On Off Trouble-free operation.
Off Flashes Device error or unallowed replacement of the module
(commissioning not possible).
Off On Firmware and parameter data of the Safety
Module (SAF-001) do not correspond with the data of
th
e converter. The parameter data of the converter has
to be copied to the Safety Module (SAF-001) by
pr
essing the button S1 (long - short - short - long).
The Safety Module (SAF-001-001-xxx) has
no LEDs.