Loading...
Description of the Safety Module (SAF-001)
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
Document no.: 5.09013.07
55
of 114
8
8.11.2 Button for verification purposes
The button on the front of the Safety Module (SAF-001-000-xxx) is used to confirm the
data transfer of the default parameter data of the converter to the parameter memory of
the Safety Module (SAF-001-000-xxx). The button must be actuated as follows: Long –
shor
t – short – long (long > 1000 ms, 500 ms < short < 1000 ms, see also the chapter
ZExchanging the modulefrom page 79 onward).
H1
H2
S1
X1
SAF-001
Button S1
Type plate
Figure 17: Button S1 on the Safety Module (SAF-001-000-xxx)
The Safety Module (SAF-001-001-xxx) has no button.