Accessories and spare parts
Instruction handbook b maXX 5000
Document No.: 5.09021.16
257
of 328
11
speedtec
®
M23 Follow the instructions below if a self-made cable with speedtec
®
M23 is to be used:
1 Utilize the following
materials:
m Ca
ble: 4x0,38 + 1x(4x0,14)
m High-
density D-sub connector: 26-pin, male
m Roun
d connector: 9-pin speedtec
®
M23, female (Intercontec)
2 Fu
lly adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
Figure 112: Connecting cable for encoder with EnDat
®
2.2 speedtec
®
M23
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable
is not functionally operable and could
lead to defects, both in the encoder module and the encoder!