Line filters
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
272
of 328
11.4
Required mains filter surrounding conditions
Transport temperature range -30 °C to +70 °C
Transport climate class (K) 2 K 3
1)
Storage temperature range -30 °C to +70 °C
Storage climate class 1 K 4
5)
Operating environment Outside of residential areas
2)
Operating temperature range T
B
3)
Min. 5 °C to max. 55 °C
Derating of the rated current as of 40 °C by 1.4% / °C
Operating climate class 3 K 3
6)
Installation altitude Up to 2000 m above MSL
Derating of the rated current as of 1000 m by 3% / 100 m
Relative humidity (operating) 5% to 85% non-condensed
6)
Ionizing and non-ionized radiation < Measurable range
Vibration, shock and continuous
shock
Drop height (packaged) max. 25 cm
4)
Drop height (packaged) Max. 25 cm
Degree of contamination 2
Environmental conditions
(EN 60721-3-3)
3 K 3, 3 B 1, 3 C 3
except f
or salt spray, 3 S 2, 3 M 3
1)
EN 60721-3-2
2)
If used in residential areas, high-frequency interference must be expected (EN 61800-3, 6.4.2.1)
3)
Rated temperature = 40 °C
4)
EN 61800-2, Chapter 4.3.3
5)
EN 60721-3-1
6)
EN 60721-3-3
Electrical data of the mains filter
NOTE!
The rated current of the filters that are use
d must be larger than or have same RMS-
value as the actual mains current (actual mains current = RMS-value of the mains
cur
rent during the entire cycle time of the drive). During short-time operation (S3), the
RMS-value is calculated as follows:
I
rms
1
T
---
i
2
0
T
dt=