BM5328 BM5328-A BM5334 BM5334-A
Input rated po
wer
1)
16.8 kW 22.4 kW
Input rated current (I
eff
)
1)
26.5 A 35.5 A
DC link voltage (U
DC
)
1)
60 V - 760 V
DC link capacitance (internal) 495 µF 660 µF
DC link discharge time
(internal DC link capacitance)
300 s 480 s
Output voltage
(U
AC
)
1) 3)
0 - 500 V
Output frequency at 4 kHz
4)
0 - 450 Hz
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at 4 kHz
4)
30 A
28 A at UL
40 A
Output rated current (I
AC
RMS)
1) 2) 5)11)
at 8 kHz
4)
21 A 28 A
Output rated current (I
AC
RMS)
1) 2) 5)11)
at 16 kHz
4)
12 A 16 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at 4 kHz
4)
60 A 60 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at 8 kHz
4)
42 A 42 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at 16 kHz
4)
24 A 24 A
Short-time operation KB 200 % 150 %
Max. length of tim
e peak current
6) 10)
Refer to ZLoad cycle accor
ding EN61800-6as from page 75
Power loss with regard to power supply Max. 230 W Max. 310 W
Power loss with regard to control voltage supply
(air-cooled)
7)
Max. 45 W Max. 40 W
Power loss with regard to control voltage supply
(cold plate cooling)
7)
Max. 37 W - Max. 35 W -
Current of the integrated brake control
(option)
8)
Max. 4.0 A
Cooling air requirement power heat sink 35 m
3
/h 55 m
3
/h
Cooling air velocity power heat sink - > 5 m/s - > 5 m/s
Cooling air requirement internal space of device 10 m
3
/h - 10 m
3
/h -
Technical data
Instruction handbook b maXX 5000
Document No.: 5.09021.16
69
of 328
3
Footnotes refer to Zpage 73.