2.5 Transport, bearing lock, intermediate storage
Transport:
Suitable lifting tackle must be used, e.g. belt webbing, loop belts etc. If provided, the
lifting lugs of the motor can be used for lifting.
The motor connectors are not allowed to be used for securing for transport or as lifting
eyes.
The regulations of the respective countries must be adhered to during transport. Lifting
devices and transport and load suspending devices must comply with the relevant
regulations.
The Baumüller DA - W series electric motors weigh approx. 1400 kg. Please refer to the technical
documentation which accompanies the product for the exact information on weight.
The motor shaft and the connection surfaces must be protected against corrosion. The motor may
only be transported with a shaft protection cover; damage to the motor shaft must be avoided.
Bearing lock (for motors with cylinder roller bearings only):
On motors with cylinder roller bearings, the runner must be blocked at the end of the
shaft in order to prevent damage during transit.
The transport protector must
be used every time the machine is moved.
If this lock can no longer be used due to mounting of a drive element, other suitable
means must be employed for axial fixing of the rotor for transport.
Intermediate storage:
If a motor is not to be commissioned immediately after delivery, it should be stored inside a building
in a dry, dust-free and low-vibration room (V
eff
≤ 0.2 mm/s).
The electric motors should be stored at as uniform a temperature as possible, not outside of the
temperature range -15 to +60 °C, for no more than two years. Elevated storage temperatures
within the framework of the working temperature accelerate the rate at which seals and bearing
grease deteriorate and therefore have a negative impact on the service life even before the unit
has been commissioned. Direct exposure to incident solar radiation, UV light and ozone also lead
to an ageing of the gaskets and must be avoided!
To avoid frost damage, cooling water should be removed at temperatures < 3°C.
Please note that the warranty periods commence from the date of delivery. For this reason, we
recommend that storage periods be kept to a minimum.
2.6 Installation conditions, cooling details
Surroundings:
The motor can be installed indoors in dusty or damp ambient conditions and normal climatic
conditions. The motor must not be brought into contact with aggressive, corrosive, abrasive or
plastic-dissolving media.
Consultation with the motor manufacturer is essential in the case of installation outdoors.
For ambient conditions comp. Section 2.4 and the technical documentation that accompanies the
product.
Cooling details:
Size 100 132 160 180 225 280
Connections VL
RL
1
1
1
1
2
2
2
2
2
2
2
2
Connecting thread G1/2“ IG G1/2“ IG G1/4“ IG G1/4“ IG G1/4“ IG G3/8“ IG
Direction of flow as req. as req. as req. as req. as req. as req.
TAM 00612 10
DA 100 – 280 W 06 / 2011
Three-phase synchronous motor water-cooled English