18.0 External Low Voltage Controls
© Baxi Heating UK Ltd 2013
18.4 Connecting the Optional 7 Day Wired Sensor
NOTE: The yellow link wire between terminals 1 & 2 on
terminal block M1 MUST be removed when fitting the
7 Day Wired Sensor.
1. Ensure that the power to the boiler is isolated.
2. Remove the backplate from the unit by pressing down on
the rear tab and easing apart.
3. Locate the sensor and use wiring as described in the
literature supplied with it.
4. Pass the wiring through the slots in the backplate and
connect as shown opposite to 2 & 3 on the sensor backplate
and 1 & 2 of boiler terminal M2.
5. Complete fitting as described in the sensor literature, turn
the power back on and set the controls to the requirements of
the user.
Optional 7 Day Wired Sensor
1. Press Securing Tab
2. Ease away from Backplate
1 23
Programmer & Room
Sensor Backplate
Boiler Wiring
Terminal M2
Low
Voltage
Terminal
Block
Boiler
Mains
Voltage
Terminal
Block M1
1
2
IMPORTANT !
IMPORTANT !
When fitting Low
Voltage Controls
remove the Ye llow Link Wire
from the Boiler Terminal Block M1