Appliance requires adequate floor load-bearing capacity; use load-distributing plates if needed.
Installation must allow access for cleaning the appliance, flue gas connector, and chimney flue.
Take precautions against water leakages in tanks; ensure drain lines and safety systems are suitable.
Boiler must be installed in a dry ambient, protected from frost (0° to 45°C range).
Take measures against rain or water from condensing waste gases; chimneys must meet standards.
Mount an air relief device on the hot water outlet pipe as per installation guidelines.
Use original packaging; protect the boiler from damage during transport and handling.
Check installation connection slants with a water gauge; ensure no air is present in the system.
Never pump water to a working boiler; use low-temperature water for non-operating boilers to avoid damage.
Ensure combustion air is free from elements causing corrosion, like water steams or cleaning substances.
Heating water must be pure, free from residues, and have hardness below 20°F to prevent corrosion.
Boiler body covered with glass wool and aluminum foil for high insulation and low heat loss.
Features adjustable flue gas flap for combustion control and water distributing plate for high efficiency.
Doors with double side opening hinges; easy coal loading and ash discharging with two ash trays.
Fan and pump controlled automatically or manually via thermostat and control panel.
Explains the "2 Pass - Firing model" with components like turbulators, chimney, and ash tray.
Allows switching off the fan on Linyitomat 80 plus models for combustion without fan.
Fixable and adjustable flue gas flap system controls combustion by throttling the flap for optimal draught.
Instructions for first burning with normal sized coals, including fan and door settings, and initial coal loading.
Details on loading coal to start charcoals, skewering, and last loading for continuous burning.
Emphasizes correct fan electrical connections for proper air supply to the combustion chamber.
Load boiler with coal before it completely burns for economic and efficient operation.
Procedures for morning ash skewering and loading coal after ignition and flame establishment.
Recommends cleaning the boiler at least once a week for efficient operation.
Explicitly states not to use cokes.
Instructions for first burning with powder coal, including wood ignition and initial coal loading.
Boiler flue gas temperature can range from 180-300°C under normal conditions.
Mandatory return and outlet water temperatures must be within specified limits for Linyitomat PLUS boilers.
Provides a method to calculate the auxiliary pump flow capacity for LP 80 models based on temperature difference.
Checks for circulation pump issues and sufficient coal level to maintain water temperature.
Provides dimensions (A and B) for the fuel loading mouths of different Linyitomat PLUS models.
Lists pump types and their corresponding required open expansion vessel capacities for Linyitomat Plus boilers.
Details technical specifications for DAB pumps (VA 35/130, VA 65/130, A 50/180XM, A 56/180XM), including revolutions, power, and capacitor.
Details boiler dimensions (height, width, depth) and pipe inlet/outlet diameters for different models.
Lists boiler water capacity, expansion vessel volume, and circulating pump models and weights.
Includes max operating pressure, test pressure, flue gas temperature, and mass flow rate at nominal output.
Provides nominal heat output, heat output range, and boiler efficiency class/percentage for coal.
Covers temperature controller settings, rated input power, voltage, and frequency for the boilers.
Displays performance curves for VA 35-VB 35 pumps showing flow rate versus head and power.
Displays performance curves for A 50/180 XM pumps showing flow rate versus head and power.
Displays performance curves for A 56/180 XM pumps showing flow rate versus head and power.
Provides dimensional data (L, L1, L2, B, etc.) for various pump models.
Introduces the control panel with thermostat, lamps, and selection switch for automatic or manual operation.
Explains how the electronic thermostat controls fan and pump in automatic mode based on water temperature.
Details manual operation where fan and pump are controlled by their respective buttons.
Thermostat adjusts temperature; it stops the fan if water temperature exceeds the set point.
Shows the wiring diagram for the electronic control board, including switches and fan/pump connections.
Illustrates the wiring path for the automatic mode, connecting to the control board and thermostat.
Shows the wiring for manual mode, connecting to the control board and individual fan/pump switches.
Shows the overall electrical connection layout for the boiler, including power supply and component connections.
Details specific wiring for pump, fan, and thermostat using various cable types and lengths.
Explains the color coding for wires (e.g., brown, black, blue, red, yellow-green) and their connections.
Diagram showing the installation of the expansion tank with steel pipes and bypass valve.
Illustrates the connection of the expansion tank water level indicating pipe.
Highlights the requirement for the vent to be open during installation.
Shows the scheme for connecting an open expansion tank to the boiler and hot water tank system.
Illustrates the placement of manometer and hydrometer in the boiler's water circuit.
Indicates the safety valve and the potential need for a mixture valve based on water supply pressure.
Depicts the water supply connection and the service circulating line setup.
Recommends annual service by Baymak official services for optimal performance and longevity.
Details coal loading from the middle door, use of ash cleaning door, and safety checks for flammable materials.
Advice on managing chimney restriction (clack) during first burning to ensure proper flame development.
Advises cleaning the boiler at least once a week for efficiency, depending on fuel quality and ash rate.
Instructions for fan issues, circulation pump service, and overall boiler servicing at the end of each winter season.
Discusses variable fuel loading intervals based on fuel type and calculating fuel amount from input power.
Clean cover and control panel every 15 days or when required.
Clean smoke pipes weekly and inner boiler daily; remove ashes and coal remnants.
Clean flue gas box every 15 days or as needed, depending on fuel type.
Clean combustion chamber, turbulators, and flue gas box by opening the top door and using a brush.
Apply to authorized service for water leaks; check electrical connection for pump issues.
Check electrical connection for fan issues; discharge boiler and contact service for power loss or damaged cables.
Open bypass valve, close doors/clamp, check expansion tank; if temperature doesn't drop, add sand/ash to coal.
Do not fill cold water into the boiler while it is working to prevent damage.
Ensure warranty certificates are approved; product must be used as defined in the manual.
Warranty void for faults from abnormal conditions, inappropriate usage, transport damage, or unauthorized intervention.
Out of warranty for lack of periodic maintenance, faulty installation, incorrect capacity selection, or wrong fuel.
Warranty void if boiler/installation freezes or if water hardness exceeds 20°F, causing failure and damage.