BA series pumps
Pump unit with diesel drive 1401
8.26
Alternator - Inspect
Perkins recommends a scheduled inspection of the alternator. Inspect the alternator for loose
connections and correct battery charging.
Alternator and Fan Belts - Inspect/Adjust
Inspection
To maximize the engine performance, inspect the belts for wear and for cracking.
Battery Electrolyte Level - Check
When the engine is not run for long periods of time or when the engine is run for short periods, the
batteries may not fully recharge. Ensure a full charge in order to help prevent the battery from freezing.
If batteries are correctly charged, the ammeter reading should be very near zero, when the engine is in
operation.
WARNING
All lead-acid batteries contain sulfuric acid which can burn the skin and clothing.
Always wear a face shield and protective clothing when working on or near
batteries.
1. Remove the filler caps. Maintain the electrolyte level to the "FULL" mark on the battery.
If the addition of water is necessary, use distilled water. If distilled water is not available use clean
water that is low in minerals. Do not use artificially softened water.
2. Check the condition of the electrolyte with a suitable battery tester.
3. Install the caps.
4. Keep the batteries clean.
Clean the battery case with one of the following cleaning solutions:
Use a solution of 0.1 kg (0.2 lb) baking soda and 1 L (1 qt) of clean water.
Use a solution of ammonium hydroxide. Thoroughly rinse the battery case with clean water.