LCD display
«Mode»-button
«Data»-button
Plug-in connection, 11-pin
Info LED
1
2
Mechanical mounting in the switch cabinet
3
Electrical connection
Safety instructions
1
These devices and their accessories may only be operated in compliance with the operating instructions (intended use)!
These devices and their accessories may only be commissioned by trained and qualified personnel.
These devices may only be operated with the intended supply voltage and parameters.
If malfunctions occur that cannot be rectified, shut down the device and send it in for repair.
These devices are only allowed to be repaired by the manufacturer. Tampering and alterations are not permitted. This will invalidate all guarantee and
warranty claims.
The 11-pin version of the ProLoop is mounted onto a mounting rail base (ES 12). This base is ordered and delivered separately as it is not included in the
scope of delivery.
The loop connection wiring to the loop detector must be twisted at least 20 times per meter.
Please wire the device in accordance with the terminal assignment. Make sure the terminals are assigned correctly.
General
Explanation of the LCD display Explanation of the LED
Standard display
1-loop device
Standard display
2-loop device
Control button Control button
Red & green: Start-up phase
Green: Operation
Red & green: Configuration
Flashing green: Loop activated
Flashing red: Error
Flashing
red + green: Simulation
The settings of the ProLoop devices in this chapter are shown and explained for the 1-loop device. The settings for loop 2 of a 2-loop device should be
made using the corresponding method.
4
Value and parameter setting options
LCD display and controls
4.1
Check the electrical connection (base assignment) when exchanging a loop detector from another manufacturer.
A:
Supply
voltage
connection
B:
Loop connection
1-channel device
C1:
Loop connection
2-channel device
C2
1)
:
Loop connection
2-channel device
D:
Relay connection
output 1
E:
Relay connection
output 2
1)
Only applies to ProLoop2 with the designation «... .S.78. ... .»