5.8 Connection of the external encoder supply
5.8.1 Incremental, HTL, SIN/COS, SSI
1)
SMX
Spannungs-
überwachung
der externen
Geber-
versorgungs-
spannungen
X15
1
2
L+_ENC1
L-_ENC1
X31
L+_ENC1
L-_ENC1
9
2
L+_ENC1-2
L-_ENC1-2
X33
L+_ENC2
L-_ENC2
9
2
L+_ENC2
L-_ENC2
X32
L+_ENC2
L-_ENC2
9
2
L+_ENC2-2
L-_ENC2-2
X34
L+_ENC2
L-_ENC2
9
2
X13
1
2
X17
1
2
X15
1
2
X19
1
2
1)
1)
2)
2)
3)
3)
1) Only SMX 11-2(/2) and SMX 12-2(/2)
2) Only SMX 12(/2) and SMX 12-2(/2)
3) Only SMX 12-2(/2)
The SMX module supports encoder voltages of 5V, 8V, 10 V, 12V and 24V, which are internally
monitored in accordance with the chosen configuration.
If an encoder system is not supplied through the SMX module, a supply voltage still needs to be
connected to terminal X13 or X15 and configured accordingly.
The encoder supply must be protected with a fuse of max. 2A.
Safety note:
The GND connection of the encoder must be connected to the GND of the SMX
Monitoring of the supply voltage in accordance with the chosen nominal voltage:
Nominal voltage
Minimum voltage
Maximum voltage
5 VDC
4,4 VDC
5,6 VDC
8 VDC
7 VDC
9 VDC
10 VDC
8 VDC
12 VDC
12 VDC
10 VDC
14 VDC
20 VDC
16 VDC
24 VDC
24 VDC
20 VDC
29,5 VDC
Monitoring of
external encoder
supply voltages