EasyManua.ls Logo

BBH SMX 12-2 - 5.12.2.7 HTL - Sensor; 5.12.2.8 Resolver

Default Icon
234 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation manual
HB-37350-810-01-51F-EN SMX Installation manual.docx Page 177 of 234
Version: 50F
5.12.2.7 HTL Sensor
Signal level. 24V/0V
Physical Layer: Push/Pull
Measuring signal A/B track with 90° phase difference
Max. counting pulse frequency: 200 kHz on X27/28 or X29/30
(only SMX11-2/12-2)
Diagnoses:
Diagnosis
Parameters
Fault threshold
Supply voltage monitoring
Fixed values
5 V, 8V, 10V, 12V, 20V,
24V
+/- 20 % +/-2 %(measuring
tolerance)
Monitoring of differential level
on input
Fixed value 24 V
+/- 20 % +/-2 %(measuring
tolerance)
Monitoring of the counting
signal separated for each
track A/B
Fixed value
DP > 4 increments
5.12.2.8 Resolver
Measuring signal: SIN/COS track with 90° phase difference
Max. counting pulse frequency 2 kHz/pole
Resolution: 9 bit / pole
Master-Mode:
Frequency reference signal 8 kHz
Slave-Mode
Frequency reference signal 6 - 16 kHz
Reference signal form: Sinusoidal, triangle
1)
on X31/32
2)
on X33/34
Diagnoses:
Diagnosis
Parameters
Fault threshold
Monitoring of ratio
Fixed values
2:1, 3:2, 4:1
+/- 20 %
+/-2 %(measuring tolerance)
Monitoring of signal
amplitude SIN²+COS²
Fixed value
<2.8 V
+/-5 % (measuring tolerance)
Monitoring of phases A/B
Fixed value 90°
+/- 7°
+/-2°(measuring tolerance)
Monitoring of reference
frequency
Fixed values
6 .. 12 kHz in steps of 1 kHz,
14 kHz, 16 kHz
+/- 20 %
+/-5 %(measuring tolerance)
Form of reference signal
Sinusoidal, triangle, no
monitoring
40 % form deviation
Monitoring of counting signal
/ signal phase quadrant
Fixed value
+/- 45°

Table of Contents

Related product manuals