EasyManua.ls Logo

BBH SMX 12-2 - 12.3.5.2 Beispiel für Vorgabe HW

Default Icon
234 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation manual
HB-37350-810-01-51F-EN SMX Installation manual.docx Page 216 of 234
Version: 50F
12.3.5.2 Beispiel für Vorgabe HW
Safety function
Safely reduced speed
SF
2.2
Safely monitored limited speed with door open
Type
Designation
Function
Design
Characteristic data
Note
Archite
cture
MTTF
D
[Years]
PFH
[1/h]
B10d
Source
DC
[%]
Source
Sensor
Sensor 1
Door lock Monitoring of the
access door
A 3.1
4
10000
0
Data
sheet
99
Inst.
manual
op. SMX
Sensor
2.1
Incremental encoder Motor
feedback
SIN/COS
G 1.1
4
30
Gen.
specificati
on
99
Inst.
manual
op. SMX
Cat. 4 in
connectio
n with
selection
SMX
PES
Safety
PLC
Central safety PLC for control and
evaluation of safety relevant
functions
A 4.1
1,4 E-8
Data
sheet
SMX
Actuator
STO
Safe Torque Off on inverter
A 5.1
4
150
Data
sheet
inverter
99
Inst.
manual
op. SMX
Cat. 4 in
connectio
n with
dual-
channel
Mains
contactor
Contactor in mains line of inverter
K 5.1
4
20 E6
Data
sheet
contactor
99
Inst.
manual
op. SMX
Cat. 4 in
connectio
n with
dual-
channel

Table of Contents