HB-37350-810-01-51F-EN SMX Installation manual.docx Page 24 of 234
Version: 50F
• Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
• Complete speed and position-based safety functions for drive monitoring in accordance
with IEC 61800-5-2 are integrated in firmware
o Spatial functions for safe speed and are monitoring are possible
• Parameter management for expansion modules in base device
• Comprehensive diagnostics functions integrated
• Coded status display via front-side 7 segment display and status LEDs
• Multifunction buttons (quit, start, reset) can be operated from the front side
• Optional: Communication interface
o Standard and safe field bus protocols for communication with a higher level
controller
o Safe cross communication (SMMC) for data exchange between multiple base
devices
o Safe remote I/O communication for data exchange with distributed I/O systems
See: Chapter 3.2.4.3 Optional universal communikation interface
• CAN-communication in connection with the SMX5x for diagnose via backplane bus
system mounted on top-hat rail (see communication module)
• Assembly on top hat rail
• The mechanical structure of SMX11(4x, /x
(1)
) differs from the figure. (see mechanical
data)