Installation manual
HB-37350-810-01-51F-EN SMX Installation manual.docx Page 36 of 234
Version: 50F
Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
Parameter management for expansion modules in base device
Comprehensive diagnostics functions integrated
Coded status display via front-side 7 segment display and status LEDs
Multifunction buttons (quit, start, reset) can be operated from the front side
Optional: Communication interface
o Standard and safe field bus protocols for communication with a higher level
controller
o Safe cross communication (SMMC) for data exchange between multiple base
devices
o Safe remote I/O communication for data exchange with distributed I/O systems
See: Chapter 3.2.4.3 Optional universal communikation interface
CAN-communication in connection with the SMX5x for diagnose via backplane bus
system mounted on top-hat rail (see communication module)
Assembly on top hat rail
Extended functionality:
o allows the connection of 2 rotary encoders per axis(SSI, Sin/Cos, TTL, Proxi)
o 2. encoder interface also supports HTL (200 kHz), Sin/Cos High-Resolution and
Resolver
The mechanical structure of SMX12-2/12-2A(/2, /4x, /x
(1)
) differs from the figure.
(see mechanical data)
SMX 12-2A(/2) Variant (analogue) with 2 analogue inputs