EasyManua.ls Logo

BBH SMX 12-2 - Technical characteristic data SMX31;31 R;31 R-4(;2)

Default Icon
234 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation manual
HB-37350-810-01-51F-EN SMX Installation manual.docx Page 40 of 234
Version: 50F
Technical characteristic data SMX31/31R/31R-4(/2)
Safety related characteristic data
Pl acc. to EN ISO 13849-1
PL e
PFH / architecture
9,2 FIT
/Cat 4
1)
plus in SMX31R/31R-4
1-channel per Rel 20 FIT
(
max. 8)
2-channel per Rel 1,0 FIT
(
max. 4)
SIL acc. to IEC 61508
SIL 3
Proof test interval
20 years = max. operating period
General data
Max. no. of expansion modules
-
Interface for expansion modules
T-bus connector, pluggable in top-hat rail
Number of safe digital inputs
12 (OSSD capable)
Number of safe digital outputs
-
Number of safe digital I/O
SMX31(/2)
10
SMX31R(/2)
2
SMX31R-4/2
6
Number of relay outputs
SMX31R(/2)
8
SMX31R-4/2
4
Number of safe analogue inputs
-
Number of auxiliary outputs
2
Number of pulse outputs (clock outputs)
2
Type of connection
Plug-in terminals with spring or screw connection
Axis monitoring
-
Encoder interfaces (D-Sub / screw terminal)
-
Encoder technology (See table encoder specifications)
-
Electrical data
Fuse
X11.1
min. 30 VDC; max. 3,15A
Max. power consumption (logic)
2,4W
Rated data digital inputs
24 VDC; 20 mA, Typ1 acc. to EN 61131-2
Rated data digital outputs
Auxilary outputs
24 VDC; 250mA
Pulse outputs
(clock outputs)
24 VDC; 250mA
Digital I/O
24 VDC; 250mA
Rated data
relays
Normally open DC13
AC15
24 VDC; 2A
230 VAC; 2A
Normally closed DC13
(Read back contact)
24 VDC; 2A
Rated data analogue inputs
-
SMXGen2 (/2)
Fuse
X11.1
min. 30 VDC; max. 10A
Max. power consumption (logic)
7,1W
Rated data digital outputs
Digital I/O 01 05
06 10
24 VDC; 0,5A
24 VDC; 2A ***
Electrical data (For UL only) SMXGen2 (/2)
Rated data digital outputs
Auxilary outputs
24 VDC; 250mA (G.P.)
Digital I/O 01 05
24 VDC; 0,5A (G.P.)
06 10
Temperature rating
30°C
24 VDC; 2A (G.P.)
Temperature rating
50°C
24 VDC; 1,8A (G.P.)
Max. total current
10A
Rated data
relays
Normally open
24 VDC; 2A (Pilot Duty)
120 VAC; 2A (Pilot Duty)
Normally closed
(Read back contact)
24 VDC; 2A (Pilot Duty)
Environmental data
Temperature
0°C … +50°C operation
-25C° … +70C° storage and transport
Class of protection
IP 20
Climatic category
3k3 acc. to DIN 60 721-3
Min-, Maximum relative humidity (no condensation)
5% - 85%