Technical characteristic data SMX1x/4x
Safety related characteristic data
Pl acc. to EN ISO 13849-1
n.a.
PFH / architecture
n.a.
SIL acc. to IEC 61508
n.a.
Proof test interval
n.a.
General data
Fieldbus interface
1
Type of connection
Standard acc. to field bus type
Max. size PAA (standard)
2x64 Bit
Max. size PAE (standard)
32 Bit
Max. size PAA PAE (safe)
12 Byte
Type Update time for data
16 ms
Electrical data
Power consumption
Max. 0,5W
Field bus ratings
Standard acc. to field bus type
Environmental data
Temperature
0°C … +50°C operation
-25C° … +70C° storage and transport
Class of protection
IP 20
Climatic category
3k3 acc. to DIN 60 721-3
Min-, Maximum relative humidity (no condensation)
5% - 85%
EMC
EN 61000-6-2, EN 61000-6-4, EN 61000-6-7, EN
61800-3, EN 61326-3, EN 62061
Operating altitude
2000m
Overvoltage category
III
Degree of pollution
2
Mechanical data
Dimensions (HxDxW [mm])
100x115x22,5
Weight (g)
110