Alaris™ GW 800 Volumetric
Pump
(with Set Detection Mode disabled)
Directions For Use
en

Table of Contents

Other manuals for BD Alaris GW 800 Series

Question and Answer IconNeed help?

Do you have a question about the BD Alaris GW 800 Series and is the answer not in the manual?

BD Alaris GW 800 Series Specifications

General IconGeneral
Volume To Be Infused (VTBI)0.1 to 9999 ml
TypeInfusion Pump
Flow Rate Accuracy±5%
Power Requirements100-240 VAC, 50/60 Hz
Battery TypeLithium Ion

Summary

Controls and Indicators

Controls

Details the function of buttons like ON/OFF, RUN/HOLD, CLEAR/MUTE, PRIME/BOLUS, etc.

Operating Precautions

Infusion Sets

Guidelines for using BD infusion sets, anti-siphon valves, and flow sensors.

Operating Precautions

Hazards

Details explosion, fire, electrical shock, and ESD hazards.

Getting Started

Initial Set Up

Steps for checking Pump, items supplied, and charging.

Power On/Off

Procedures for powering the Pump on and off.

Automatic Set Detection

Explains the automatic detection of compatible infusion sets.

Getting Started

Getting Started

Loading an Infusion Set

Step-by-step guide to correctly load the infusion set.

Priming the Infusion Set

Instructions for priming the infusion set before use.

Starting the Infusion

Standard Mode

Steps to start an infusion in standard mode.

Standard Mode with VTBI / Time Infusion on

Steps for starting infusion with VTBI and time settings.

Micro Mode

Steps to start an infusion in micro mode.

Micro Mode with VTBI / Time Infusion on

Steps for starting infusion in micro mode with VTBI/time.

Secondary/Piggyback Infusions

Secondary/Piggyback Infusions

How to set up and run secondary infusions.

Basic Features

Rate Titration

Adjusting infusion rate during an infusion.

Bolus Infusions

How to administer a bolus dose.

Basic Features

Changing the Infusion Set

Procedure for replacing the infusion set.

Changing the Fluid Container

Procedure for replacing the fluid container.

Basic Features

Clearing Air-In-Line

Steps to clear air from the infusion line.

User Selectable Options

Setting the Occlusion Pressure Level

Adjusting the pressure limit for occlusion alarms.

Configurable Options Sheet

Alarms

Alarms

Table of display messages, causes, and actions for all alarms.

Advisories

Flow Sensor Operation

Compatible Dedicated Infusion Sets

Maintenance

Routine Maintenance Procedures

Guidelines for pump maintenance and servicing.

Cleaning and Storage

Specifications

Specifications

Alarm Conditions

List of alarm conditions and their causes.

System Accuracy

Rate and bolus volume accuracy specifications.

Specifications

IrDA, RS232 and Nurse Call Specification

Trumpet and Flow Rate Curves

Technical Description

Air-in-Line

Details on ultrasonic transducers for air detection.

Downstream Occlusion Pressure

How the pump monitors downstream pressure.

Upstream Occlusion Pressure

How the pump monitors upstream pressure.