Split Air Conditioner | Aire Acondicionado Split | Ar Condicionado Split
Use a power supply circuit and circuit breaker certied in accordance
to local safety regulations.
Install a circuit breaker to avoid malfunctions.
An all pole disconnection switch with a contact separation of at least 3
mm across poles should be permanently connected.
This includes a circuit breaker with suitable capacity. The air switch
should include a magnet buckle and heating buckle function to
protect against short-circuits and overloads.
The air conditioner should be properly grounded. Incorrect grounding
may cause an electric shock.
Use a certied power cord.
Make sure the power supply matches the requirements of the air
conditioner. Please install the appropriate power supply cables before
using the air conditioner.
Properly connect the live , neutral and grounding wires in the socket.
Be sure to cut o the power supply before proceeding with any
electrical or safety work.
Do not connect the power before nishing installation.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied persons in order
to avoid a hazard.
The refrigerant circuit will be very hot, so the interconnection cable
must be kept away from the copper tube.
The appliance must be installed in accordance with national wiring
regulations.
Installation must be performed in accordance with the standard
requirements.
The air conditioner is a class 1 electric appliance. It must be properly
grounded with a specialized grounding device by a professional.
Please make sure the appliance is always eectively grounded, to
avoid the risk of electric shock.
The yellow-green wire in the air conditioner is the grounding wire,
which can’t be used for other purposes.