 If a vacuum is not possible, make a manifold so that refrigerant can
be removed from various parts of the system.
 Make sure that cylinder is situated on the scales before recovery
takes place.
 Start the recovery machine and operate in accordance with
manufacturer’s instructions.
 Do not overll the cylinders (no more than 80 % of the volume
liquid charge).
 Do not exceed the maximum working pressure of the cylinder, even
temporarily.
 When the cylinders have been lled correctly and the process
completed, make sure the cylinders and the equipment are removed
from the site promptly and all isolation valves on the equipment are
closed o.
 Recovered refrigerant shall not be charged into another refrigeration
system unless it has been cleaned and checked.

Equipment shall be labelled stating that it has been de-commissioned
and emptied of refrigerant. The label shall be dated and signed. Ensure
that there are labels on the equipment stating the equipment contains
ammable refrigerant.
16. Recovery
• When removing refrigerant from a system, either for service
or decommissioning, it is recommended good practice that all
refrigerants be removed safely.