Category | Personal Care Products |
---|---|
Measurement Principle | Electrochemical Sensor |
Resolution | 1 ppm |
Device Type | Breath CO Monitor |
Usage | For monitoring carbon monoxide levels in breath |
Display | LCD |
Breath Sample Type | Exhaled Breath |
Dimensions Alternative | 120 mm x 50 mm x 25 mm |
Operating Humidity | 10% to 90% RH (non-condensing) |
Connectivity | USB |
Measurement Range | 0-500 ppm |
Response Time | Less than 10 seconds |
Battery Life | Approximately 1000 tests |
Weight Alternative | Approximately 100 grams |
Specifies the piCO+ Smokerlyzer's use by healthcare professionals in smoking cessation.
Explains what carbon monoxide is and its physiological effects on the body.
Describes CO and COHb correlation and different user profile cut-off points.
Steps for turning on the device, attaching accessories, and preparing for a test.
Guidance on inhaling, holding breath, exhaling, and viewing results.
How to end a test, remove the D-piece, and prepare for the next test.
Lists all items included in the piCO+ Smokerlyzer package.
Details technical specifications like concentration range, accuracy, power, and dimensions.
Identifies and describes the main physical parts of the piCO+ instrument.
Details the location and function of ports, buttons, and indicators on the device.
Symbols for battery status, user profiles, and sounder settings.
Icons for breath test stages, readings, and calibration procedures.
Icons related to user profile selection, help, and D-piece reminders.
Crucial safety precautions for operating and handling the piCO+ device.
Guidelines for cleaning the instrument and D-piece to maintain hygiene.
Information on regular maintenance tasks and calibration prompts.
Instructions for safely replacing and handling the device's batteries.
Explains button functions, powering on the unit, and initial warm-up.
Details the zeroing process, error handling, and preparing the patient for a breath test.
Guides on breath holding, countdown, exhalation, and reading interpretation.
Covers sounder control, test completion, auto-off, and settings references.
Overview of the calibration kit components and initial setup.
Steps to set the instrument's zero point using ambient air.
Procedure for connecting and applying 20ppm CO calibration gas.
How to check calibration results, handle failures, and finalize the process.
How to navigate to and enter the set-up mode for configuration.
Guide to choosing between adult, adolescent, or custom user profiles.
Explains how the sounder operates during breath tests and countdowns.
Steps to turn the sounder on or off within the set-up menu.
How to temporarily silence the sounder during or after a test.
Solutions for units failing to turn on or showing low battery indicators.
Explains potential factors leading to inaccurate CO readings.
How to resolve issues encountered during the fresh air zeroing process.
Troubleshooting steps for when the calibration process fails.
Instructions for establishing a USB connection between the piCO+ and a computer.
Guidance on launching and operating the COdata+ software.
Information on accessing and managing custom user profiles via the software.
Explains what carbon monoxide is and its harmful effects on the body.
Details what the breath test measures and how CO levels change over time.
Clarifies ppm and %COHb units and expected reading ranges.
Advice on optimal test timing and how quickly CO is eliminated.
Steps to follow when returning the device for service or repair.
Procedures for returning equipment under warranty and after warranty expiration.
Information on required paperwork, handling fees, and carriage charges.
Lists consumable items and accessories that can be purchased.
Details the warranty period, coverage, and terms for the piCO+ device.
Outlines circumstances that will invalidate the product warranty.
Guidance on the environmentally responsible disposal of electronic instruments.