• The max. number of melting operations can be
adjusted according to the duplicating material
used:
• Keep the button depressed until the
acoustic signal sounds twice: the display
shows the max. number after the colon
(default setting: 08).
• Change the number by means of the "+" and
"-" buttons ("0" setting: no monitoring of the
melting operations).
• The number is saved after approx. 4 sec-
onds.
Timer
Example: At 4 p.m. on Friday the timer is to be set
so that the unit switches on at 6 a.m. on Monday:
8 h (Friday) + 24 h (Saturday) + 24 h (Sunday) + 6 h
(Monday) = 62 hours.
1. Keep the button depressed until the acoustic
signal sounds twice, then release it: the last
time (hours) set is displayed.
2. If necessary, change the time by pressing the
"+" and "-" buttons. Only full hours can be set.
(Holding the button down accelerates the
adjustment procedure.)
The time is saved after approx. 4 seconds.
3. To start the timer: press button briefly.
• The display shows the remaining time until
the unit is switched on (hours:minutes).
• Lamps T1 to T3 flash in succession (running
light).
Leave main power switch switched on!
The timer means the unit can be set to switch on
at a desired time. The duplicating material can be
removed after 3-4 hours, depending on the dupli-
cating material used and the manufacturer.
To stop the timer: press button (1) again briefly.
The display indicates the actual temperature of
the duplicating material.
Then press T1 - T3 as required.