DCX.Server 2/DCX.Client 2
www.stute-engineering.de
Chapter
: Software screens
15
3.2.4 Tab “X-Over”
Control the cut-off frequencies, filter types and delays for the outputs 1 to 6.
Note: You find the details to the described DCX2496 device functions in the device manual.
1
2
Lower cut off (Band- or High-pass)
Band-pass = Lower and Upper filter
type are NOT “off”
Type: Select a filter type from the list
(e.g. L-R 12 or Bessel 24)
Frequency: Adjust the filter cut-off
frequency via the slider or “±”buttons
-> Set “Upper” frequency from
previous channel as “lower”. E.g. LMH
out config. : M Lower = L Upper
3
4
Link
X-Over link “On” or “Off” (see device
manual DCX2496).
Note: Setting On/Off valid for all
outputs at the same time.
5
6
Output Gain
Adjust the gain for the selected output
via the slider or the “±” buttons
7
Delay off = Disable the delay
Delay on = Enable the delay
Warning: Wrong
settings can damage
your loudspeaker!