What to do if HPS high-pressure switch has triggered in Beko DRYPOINT RS HP50 NA Dehumidifier?
- CChristina FisherAug 14, 2025
If the HPS high-pressure switch in your Beko Dehumidifier has triggered, it could be due to several reasons. First, ensure sufficient ventilation or that the ambient temperature isn't too high. If air-cooled, clean the condenser. If water-cooled, ensure the cooling water isn't too hot and the cooling-water flow is sufficient. You can also reset the pressure switch by pressing the button on the controller. If the issue persists, the HPS pressure switch may be defective, and you should contact a BEKO service technician for replacement.