EasyManua.ls Logo

Benchmark HPA4 Firmware Upgrade Instructions

Benchmark HPA4
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HPA4/LA4
Firmware Upgrade Instructions
Cautions:
The HPA4 and LA4 circuit boards and the firmware chip can be damaged by static electricity. Use of an ESD wrist
strap is recommended. If a wrist strap is not available, hold chassis with one hand while inserting chip and moving
jumpers. Do not touch the circuit board until your other hand is making contact with the chassis.
The firmware chip will be damaged if it is inserted backwards. The white line must face the left side of the unit,
when looking from the front of the unit!
Kit Contents:
· These instructions
· Firmware Chip
· T-15 Tool (for cover removal)
Instructions:
1. Unplug the power cord and all audio cables.
2. Remove the 6 screws on the top cover with the provided T-15 Tool.
3. Remove the top cover.
4. On the main board, move the jumper at P4 so that it is on the two pins closest to the rear of the unit (see
Figure 2).
5. Insert the firmware chip in socket U11 on the main board with the white line facing the left of the unit
(see Figure 3).
6. Using Figure 3, check the positions of the jumpers (P4 on main board).
7. Using Figure 3, check the orientation of the firmware chip. The white line must face the left of the unit.
The chip will be damaged if it is inserted backwards!
8. Replace the top cover.
9. Turn the unit on. Go into the menu and select "SETTINGS RESET" and then push the "RESET" button.
10. Go into the menu and select About and check to make sure that the Firmware version displays the new
firmware number code (e.g., 1.0.2).
Reverting to old firmware:
If you wish to revert to the old firmware the entire kit can be removed (see Figure 1), but this is not necessary. The
firmware chip can be left in place. Just move jumper P4 on the main board to its original position, and the original
firmware will be activated. Repeat steps 9 and 10 after reverting. The jumper at P4 selects the on-board memory
or the field-upgrade memory chip.

Other manuals for Benchmark HPA4

Question and Answer IconNeed help?

Do you have a question about the Benchmark HPA4 and is the answer not in the manual?

Benchmark HPA4 Specifications

General IconGeneral
Input Impedance50 kOhms
Output Power6 Watts per channel into 16 Ohms
SNR>135 dB, A-weighted
TypeHeadphone Amplifier
Inputs2 x Stereo RCA, 2 x Stereo XLR
Outputs1/4" TRS, XLR balanced
Gain0 dB
Crosstalk< -130 dB at 1 kHz
THD+N<0.00006% (20 Hz to 20 kHz, 2 Vrms, 200 kHz BW)