1. Introduction
The “Wifipool Twinis be used to monitor and control pH, and redox (chlorine) , of your
swimming pool. It is fully pre-mounted. The devices need to be paired with your mobile
phone in 5 steps.
2. Unpacking
Safety instructions
The automation installation must be carried out in such a way that:
- The chlorine and acid pumps cannot work if the filter pump does not work. This can be done
by purchasing the Wifipool Twin with flow switch (ZWPX7510-P), by adding a flow switch
ZMIX0008 (preference) to the installation or by using the same or a thghter scheduler as the
filter pump.
- The chlorine and acid pumps can be switched off manually. This can be done by the on/off
button at the bottom of the dosing pump of via the app manual control.
Addition of the chemicals for the pool should be done downstream of the pool accessories such
as heating, UV lamp, filter, and downstream of the measuring probes.
Chlorine and acid react together into toxic chlorine gas. Make sure that the chemicals are placed
outside or in a very well-ventilated room, in a drip tray, that they cannot come into contact with
each other and remain out of the reach of children…
It is recommended to put the installation of the water treatment unit in bypass configuration.
Install the water treatment unit on a solid base or against the wall (always vertically).
Always keep the product upright. If the product is tilted or placed on the side, the probes cannot
measure correctly, resulting in incorrect measurements.
The product must be installed inside
The acid dosing device should not be used with hydrochloric acid (HCl).
In the event of a leak, make sure that the water or chemicals cannot run over the installation.
The electronics or device itself must never be connected to an output of a frequency converter or
a variable speed drive.
The dosing device must not be on the same current circuit as that of the variable speed converter
or ac drive used and it is at minus 3m from the dosing unit.
Calibrate the pH and Rx probes before first use and thereafter at least every 3 months.
"regularly" verify the chlorine content and pH with a color method.
3. Physical installation of your Pool Twin
1) Hang the unit in the desired place (with strong wifi signal)
2) Insert the suction cap of RX into the chlorine canister.
3) Insert the suction cap of pH into the acid canister.
It is recommended not to lower at startup- the suction cap to the bottom of the container. If
something goes wrong with the dosing, not the entire can of acid will be pumped into the pool.
4. Installation of peristaltic pumps and measurement boxes
The pairing of your Wifipool Twin with your phone, well take 6 steps :
- Installation fo the wifipool app
- Pairing of the pH presitaltic pump
- Pairing of the Redox (chlorine) peristaltic pump
- Pairing of the pH measurement box
- Pairing of the RX measurement box
- Installation of the Pool Twin automation module.