16
17
Before any intervention on the system disconnect the 230Vac line and the batteries.
Operate now the opening push-button: if the automation starts closing, press the stop push-button, discon-
nect the 230Vac and the battery and reverse the motor cables. Reconnect the battery and the 230Vac and
press the opening push-button; adjust the working speed through the trimmer B according to standard in
force and wait for the limit stop arrival.
Adjust the braking circuit intervention by positioning correctly the cam onto the limit stops and adjusting the
trimmer C for a smooth stop.
Press the closing push-button; adjust now the torque according to standard in force through the trimmer A
so as to stop the movement with a moderate effort; keep to the standard in any case.
P.N.: operate slowly onto the trimmer to avoid that the automation stops. Check the safety catches operation
and take into consideration following points:
any time STOP is pressed, the system stops and wait for a control;
the photo-electric cells intervention during the closing phase causes a complete instantaneous re-opening,
whereas there is no intervention during the opening phase.
The limit stop micro-switches have to be installed for a correct device operation.
P.N. Any time the addition of the carried out motions create some confusion, disconnect the battery and the
network for a few seconds, then apply voltage and proceed with the tests.
P.N. If there is no 230Vac network but batteries are totally loaded, it is possible to carry out 10 to 30 complete
motion cycles depending on the automation weight.
P.N. Please avoid if possible extreme adjustments of speed and rating trimmers.
P.N. The min. section of the motor cables will have to be
1,5 sq.mm for lengths up to 1 m.
2,5 sq.mm for lengths up to 3 m.
4,0 sq.mm for lengths up to 6 m.
Accessories to request
Flash-lights kit art. VE.L200/500
Springs kit art. VE.KM24
Fixed support art. VE.AF
Mobile support art. VE.AM
Pneumatical skirting art. SC.P35
Rack art. VE.RAST
Photo-electric cells art. SC.P50 / SC.P50E
Magnetic spiral art. ID.T100
Battery charger card with battery holder plate art. DA.24CB
Rod articulation art. VE.SN500.
CAUTION
The civil liability policy, which covers possible injuries to people or accidents caused by defects in construc-
tion, requires the system to be to existing standard and to use original Benincà accessories.