EasyManua.ls Logo

Beninca YAK 25 OTI - Page 29

Beninca YAK 25 OTI
84 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
EN
IBCA
During the TCA phase, the PP controls are enabled or disabled.
On: PP controls are disabled.
Off: PP controls are enabled.
(OFF)
SCL
The rapid closure is enabled or disabled. It can be activated only if TCA:ON
On: enabled rapid closure. With open gate, the photocell activation causes the automatic
closure after 3 s.
If the photocell is activated during the opening phase, the operation is completed and
closure starts after 3s
Off: disabled rapid closure.
(OFF)
PP
The operating mode of “P.P. Push button” and of the transmitter are selected.
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting
of the motor.
Off: disabled forewarning flashing light.
(OFF)
HTR
The Service Man function is enabled or disabled.
On: Service Man operation. The OPEN/CLOSE push buttons should be kept pressed for the
entire operating time.
Off: Automatic operation.
(OFF)
LTCA
During the TCA time, the blinker is enabled or disabled.
On: Enables blinker.
Off: Disables blinker.
(OFF)
Pho1
The PHOT O input is enabled or disabled in the opening phase.
On: Photocell 1 activated only in the closing phase.
Off: Photocell 1 activated in both opening and closing phases.
(OFF)
Pho2
The PHOT C input is enabled or disabled in the opening phase.
On: Photocell 1 activated only in the closing phase.
Off: Photocell 1 activated in both opening and closing phases.
(OFF)
tst1
The check on the photocell connected to PHOTO input is activated or deactivated
Before operation, the control unit checks the switching of the photocell contact.
The test shall be carried out following any command (PP, OPEN, CLOSE, radio, TCA) with engine
off before performing the manoeuvre (even partial manoeuvres). The test is not carried out when
the engine already in motion must stop and then reverse following the BAR or PHOT intervention.
If the checks are not successful, the door/gate will not move.
On: activated check on photocell.
Off: deactivated check on photocell.
(OFF)
tst2
As for TST1, but referred to PHOTC input (OFF)
bar
It changes the mode of operation of the PHOTO inputs (photocell in OPEN) and BAR in case
the sensitive safety edges are installed in the mobile opening and closing edges.
On: The PHOTO input takes on a similar function to the BAR input but inverts the motion for the
distance set with the SPIN parameter if the sensing edge to which it is connected is pressed
during the opening phase (if the photocells in CLOSE are busy, it reverses for 10 cm). The safety
edge connected to the BAR input is only active during the CLOSING phase.
Off: The intervention of the sensing safety edge connected to the BAR input stops the movement
of the gate and inverts the motion for the distance set with the SPIN parameter (if the photocell
in the inversion direction is busy it reverses for 10cm) , both in OPENING and CLOSING.
The PHOT OPEN input resumes the operation of the photocell active in opening.
(OFF)
MINV
The opening direction of the motor is selected (see Fig. 4):
On: Right side motor mount
Off: Left side motor mount
(OFF)
Horm
Enable or disable the transition from Automatic to Man Present mode.
The logic is associated with the state of the PED input.
On: If at least one of the inputs: DAS, PHOTO or PHOTC remains active (open contact)
for at least 10 seconds, regardless of the position of the door, the unit switches to Man
Present mode (only the OPEN/ CLOSE/ SWO/ SWC inputs are active), after activating the
PED command.
For further safety purposes, it is necessary that during the OPEN/CLOSE command, the
PED input is closed. Use an N.O. key for this function, with automatic release.
Off: Automatic switch disabled.
The logic also works with PHOTOTEST enabled. (OFF)
(OFF)
NUMBER OF CYCLES (Nman)
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed once more, the last 4 digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.

Related product manuals