10
ENGLISH
Long period switching off
In case of absence for long periods of time, set the mode selector
(3-g.1a)to
(OFF).
Then,closethegastappresentonthesystem.Inthiscase,anti-
frostdeviceisdeactivated:emptythesystems,incaseofriskof
frost.
4A CONTROLS
Atthebeginningofthe heating season, and occasionally during
use,makesurethehydrometer-thermohydrometerindicatescold
systempressurevaluesbetween0.6and1.5bar:thisavoidssys-
temnoiselevelsduetothepresenceofair.Incaseofinsufcient
water circulation, the boiler will switch off. Under no circumstances,
waterpressuremustbebelow0.5bar(redeld).
Ifthisconditionischecked,itisnecessarytorestorewaterpres-
sure in the boiler proceeding as follows:
-setthemodeselector(3-g.1a)to
(OFF)
-turnonthellingtap(Lg.13)untilthepressurevalueisbe-
tween 1 and 1.5 bar.
Carefullyclosethe tap. Replace the mode selectorontheinitial
position. If pressure drop is frequent, contact the Technical Assis-
tance Service.
5A LIGHT SIGNALS AND FAULTS
Theoperatingstatusoftheboilerisshownonthedigitaldisplay,
belowisalistofthetypesofdisplays.
BOILER STATUS DISPLAY
Stand-by -
OFF status OFF
ACF module lockout alarm
A01
ACF electrical fault alarm
A01
Limit thermostat alarm
A02
Airpressureswitchalarm(C.S.I.models)
Fumes thermostat (C.A.I.models)
A03
H2O pressure switch alarm
A04
NTC domestic water fault A06
NTC heating fault
A07
Parasiteame
A11
Electric calibration min and max heating
ADJ
Transient awaiting ignition 88
°C
ashing
Airpressureswitchintervention(C.S.I.models)
Fumes thermostat intervention(C.A.I.models)
ashing
H2O pressure switch intervention
ashing
External probe present
Domestic water heat request 60
°C
Heating heat request 80
°C
Anti-freeze heat request
Flame present
To restore operation (deactivate alarms):
Faults A 01-02-03
Position the function selector to
(OFF),wait5-6secondsthen
set it to the required position
(summermode)or (winter
mode).Iftheresetattemptsdonotreactivatetheboiler,contactthe
Technical Assistance Centre.
Fault A 04
Inadditiontothefaultcode,thedigitaldisplayshowsthesymbol
.
Checkthepressurevalueindicatedbythewatergauge:
if it is less than 0.3 bar, position the function selector to (OFF)
andadjust the lling tap (Lg.13)until the pressure reaches a
value between 1 and 1.5 bar.
Then position the mode selector to the desired position (sum-
mer)or
(winter).
If pressure drops are frequent, request the intervention of the
Technical Assistance Service.
Fault A 06
Theboileroperatesnormallybutcannotreliablymaintainacon-
stant domestic hot water temperature, which remains set at around
50°C. Contact the Technical Assistance Centre.
Fault A 07
Contact the Technical Assistance Centre.