1.4 Technical Data
1.4.1 Electrical data
1.4.1.1 Mains connection
Mains connection voltage,
switchable to: 115 V AC, -20% +15%
230 V AC, -20% +15%
Current at make 30 A
Fuse 6.3 A slow-blow
Frequency 50-60 Hz
Power consumption max. 600 VA
Power dissipation max. 80 W
1.4.1.2 Motor connection
Protected in case of short-circuit between motor
phases
Max. cable length 50 m
Cable diameter 0.75 mm
2
for cable length
30 m
1.5 mm
2
for cable length
>
30 m
Screen connection both sides
Motor voltage 70 V DC
Phase current in 16 stages from 0.55 to 2.8 A
Connection system pentagram
1.4.1.3 Signal connection of signal interface 1
Signal levels of the inputs correspond to the RS
422 interface; there is no electrical separation of
the inputs and outputs from the motor voltage. The
earth (GND) is connected internally to the protec-
tive conductor.
Inputs:
Low-level -0.1 V to -30 V
High-level 0.1 V to 30 V
READY output: Open Collector (npn)
U
CEsat
<1.2 V
I
max
10 mA
short-circuit proof up to 6 V DC
Pin 6 and 14 (+,- READY) are connected in parallel
with signal interface 2.
1.4.1.4 Signal connection of signal interface 2
Signal levels are designed for driving by PLC
standard signals; there is no electrical separation
of the inputs and outputs from the motor voltage.
The earth (GND) is connected internally to the
protective conductor.
Inputs:
Active high-logic inputs connected with pull-down re-
sistor
R
Pull Down
4.7 k
;
±
10%
Input voltage
Low-level 0 V to 3 V
High-level 13 V to 30 V
Outputs:
Plus-switching final control elements
Voltage supply 24 V
Ext. voltage (to GND) -30 V to +30 V
Ext. voltage for operation min. 15 V to max. 30 V
Load current 0.4 mA to 25 mA
Residual voltage for 25 mA max. 3 V
Leakage current max. 0.2 mA
Switching frequency max. 8 Hz
Short-circuit protected
1.4.1.5 Equipment protection
Type of protection IP 20 as per
DIN 40050 / IEC 529
Protection class 1
Protection circuits:
Power unit/power stage overvoltage-proof as
per VDE 0160 Cl.2
Short-circuit monitoring;
Excessive temperature recognition;
Monitoring of undervoltage and
motor phase interruption
General Discription
1 – 4 WS5-5 Doc. no. 211.347/DGB 12.92