Trouble shooting
1. If water is leaking around the hosetails, check that the supplied rubber
washers have been fitted. Check that the hose is the right size for the
hosetail and that the hoseclip has been properly tightened.
2. If water is leaking from the clamp, check that it is done up properly and
tight, and that the O-ring is present inside the filter casing.
3. If the red ball is floating at the top of the clear indicator vessel on top of
the filter, the filter needs cleaning - refer to filter maintenance on pg 4.
4. If the water turns green, check that the UV is plugged in and running
24 hours per day. If more than six months old the lamp will need replacing.
Check that the quartz sleeve is clean and clear, to allow the UV light to
penetrate the water. Check that the pump and filter have been properly
matched for the pond size.
5. If filter sponges do not spring back after cleaning, replace old sponges
for new.
Specifications
MODEL BER CODE OUTPUT POWER MAX HEIGHT
10000 BER0101 10,000 litres / 2,200 gallons 3,500lph / 770gph 18W
15000 BER0102 15,000 litres / 3,300 gallons 5,000lph / 1,100gph 24W