THE INFINITY STAIRLIFT
Page 22
FAULTS NOT SHOWN
ON DISPLAY
Board has no power, but
LED 1 is activated
•There is a live short on a safety line, un plug each
connector on the PCB until the light goes out, this will
determine which loom the short is on and you are able
to test for continuity to the chassis to find the short. The
PCB is designed to handle a short instead of requiring a
fuse.
Lift will only work
from Remote controls
•Check both arms are horizontal (arm interlock switch is
present in downside arm)
•Check key switch is turned on / wiring (wiring for
interlock is in series with the key switch)
Troubleshooting