EasyManua.ls Logo

Bestway 58389 User Manual

Bestway 58389
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
303021205565
#58389
Hmax 1.5m
bestwaycorp.com/support
Visit Bestway YouTube channel
Question and Answer IconNeed help?

Do you have a question about the Bestway 58389 and is the answer not in the manual?

Bestway 58389 Specifications

General IconGeneral
Product typeCartridge filter pump
Hose diameter32 mm
Product colorBlue, White
Intrastat code84212100
Pool capacity (max)31800 L
Pool capacity (min)1100 L
Interleaved Two of Five (ITF-14)06942138967944
Package typeBox
Package depth355 mm
Package width450 mm
Package height330 mm
Package volume59000 cm³
Package weight- g
Quantity per pack1 pc(s)
Input voltage220 - 240 V
Input frequency50 Hz
Filtration capacity5700 l/h
Quantity per pallet20 pc(s)
Weight and Dimensions IconWeight and Dimensions
Weight8660 g

Summary

Important Safety Instructions

Risk of Electric Shock

Supply via isolating transformer or RCD, plug distance, earthed source, no extension cords.

Pump Use During Occupancy Warning

Prohibits pump use while people are inside the pool, especially if the pump is damaged.

Cord Protection

Locate the cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.

Damaged Cord Replacement

If the supply cord is damaged, the appliance should be scrapped.

Pool Compatibility

Pump is for storable pools only, not permanently-installed pools.

Electrical Supply Compatibility

Using an unmatched electrical supply is dangerous and can cause catastrophic pump failure.

Electrical Safety Precautions

Turn off electrical power at the circuit breaker before working with electricity to prevent shock, injury, or death.

Plug and Grounding

Do not modify the plug or use adapter plugs; consult an electrician for grounding questions.

Pump Handling

Handle pump carefully, do not pull by cord, keep cord free from abrasions, heat, and sharp objects.

General Operation and Maintenance

User Age and Capability Guidelines

Guidelines for use by children and individuals with reduced physical, sensory, or mental capabilities.

Adult Supervision for Maintenance

Cleaning and maintenance must be performed by adults over 18 years old familiar with electric shock risks.

Winter Storage Recommendations

Disassemble and store the pool set indoors when not in use for extended periods, like winter.

Installation and Reassembly Precautions

Read instructions before each use and installation/reassembly.

Pump Placement Distance

The appliance must be placed more than 2m away from the pool (specific to France).

Electrical Installation Standards

Follow national wiring rules for electric installations and consult an electrician for questions.

Filter Media and Operation

Use only approved media, check suction openings, stop filtration during maintenance, monitor clogging.

Filter Cleaning and Replacement

Weekly cleaning recommended; replace damaged elements promptly with approved parts.

Filter Media Inspection and Disposal

Inspect filters regularly and dispose of media according to applicable regulations/legislation.

Pump Installation and Operation Details

Water Circulation Regulations

Comply with European/national regulations for water circulation, especially electrical issues.

Equipment Examination and Support

Examine equipment before use; notify Bestway of defects or missing parts; verify components.

Pump Placement and Ventilation

Place pump on solid ground with adequate ventilation, drainage, and cleaning access; avoid water accumulation.

Plug Accessibility

Ensure the plug is accessible after the pool installation.

Environmental Condition Impact

Atmospheric conditions affect pump performance; shelter pump from cold, heat, and sun.

Stopper Plug Replacement

Replace factory stopper plugs before removal or maintenance to ensure pump integrity.

Chemicals and Wet Handling

Do not add chemicals to the filter pump; do not plug/unplug with wet hands.

Unplugging Procedures

Always unplug the appliance on raining days, before cleaning, or when unattended.

Instruction Safekeeping

Safeguard instructions; contact Bestway or search website if instructions are missed.

Parts Identification and Assembly

Component List and Diagram

Diagram showing pump components and a table detailing part quantities for assembly.

Assembly Steps Illustration

Illustrations showing the sequence for connecting pump components and preparing the system.

Pedestal Fixing, Operation and Maintenance

Pedestal Fixing Requirements

Filter pump must be vertically fixed on a pedestal (min. 18kg) with specific hole dimensions.

Hydraulic Connectors Check

Imperative to check that the hydraulic connectors are not obturated.

Pump Operation Steps

Steps for operating the filter pump, including air purge, plugging into RCD/DDR.

Dry Running Prevention

Do not dry run the filter pump; ensure pool valves are fully covered by water before operating.

Pump Maintenance Procedure

Unplug pump before maintenance; steps for cleaning/replacing filter cartridge and securing cap.

Filter Cartridge Replacement Suggestion

Suggest replacing the filter cartridge with a new one every two weeks; flush the filter daily.

Winterization and Storage

Steps for winterizing: unplug, stop water, remove/discard cartridge, detach hoses, dry components, store safely.

Pump Warranty Information

Information concerning pump warranty available on the Bestway website.

Pump Disposal Guidelines

Do not dispose of as municipal waste; use separate collection facilities as per regulations.

Company and Product Information

Brand Information

Bestway brand logo and company information.

Support and Contact

Provides website for support and contact information.

Trademarks and Rights

Details on trademarks, rights reserved, and usage under license.

Global Distribution

Lists distributors and representatives in various regions like Europe, North America, Latin America, and Australia.

Manufacturing Origin

Indicates the product is made in China.

Related product manuals