EasyManua.ls Logo

BGH 17260 - Page 27

BGH 17260
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-17
(TROUBLE 6) When toaster operates, strange code can be seen on the display and stop with beep sound.
CONDITION CHECK RESULT CAUSE REMEDY
1. F-1 code.
2. F-2 code.
No continuity.
Continuity.
Continuity.
No continuity.
Continuity.
Check the
connection
between CN3
connector and
PCB assembly.
Check the
continuity of
heater.
Defective heater
Replace toaster
Assembly.
Defective
thermistor
Replace thermistor
Check continuity
of thermistor.
Defective PCB
assembly.
Replace PCB
Assembly.
No continuity. Loose connection
Connect them
tightly.
Attached
Check the CN3
connector
whether 2 wire
leads are
attached.
2 wire leads are
shorted contact
Apart 2 wire leads
as far as possible.
Seperated
Defective PCB
assembly.
Replace PCB
assembly.
3. HOT code.
Internal
temperature is
over 220 deg c
Allow the toaster to
cool down.
(Automatically fan
will blow for
3 minutes to cool
this unit)