March 2021
Installation, Operation and Maintenance Manual
MDE 257 Rev. 1
2
Reserved Passwords
Section 2: Reserved Passwords
Section 2: Reserved Passwords
The VIEW and SETUP features available through the Local Operator Interface allows the user to set
actuator characteristics according to the needs of the process and to view diagnostic
messages and status.
To enter the SETUP menu a password is required. Three levels of password are available:
1. Password level 0: This is the "user" password and consists of 4 alphanumeric characters.
The actuator is supplied with the password "0000" (four zeros) from the factory. The user
can change this factory password as described in the ICON3000 IOM.
2. Password level 1: This password allows the user all of the functionality afforded by
Level 0, but also allows the NAMEPLATE routine to be entered and changed. Nameplate
data is normally entered in the factory. The Level 1 password (not "0000") is entered in the
same fashion as Level 0.
3. Password level 2: This password offers all the functionality of Levels 0 and 1, and also
offers entry into the RESTRICTED routine of the ACTUATOR SETUP menu. Special routines
can be found within the RESTRICTED routine that are generally used to enable and disable
hardware and software modules, and calibrate the ICON3000's sensors. There is a special
procedure for entering the Level 2 password, which is as follows:
Enter VIEW and SETUP menu as described in the IOM of the actuator.
Select language.
Select SETUP mode.
Enter password:
Select the 1
st
character of password, and then press YES.
Select the 2
nd
character of password, and then press YES.
Select the 3
rd
character of password, and then press YES.
Select the 4
th
character of password, and then press YES and keep this push-button
pressed down until the display shows the message "PASSWORD CORRECT."
The button must be kept pushed down for approximately 10 seconds for the
password to be accepted.
Confirm SETUP mode.
Confirm ACTUATOR SETUP.
Scroll the ACTUATOR SETUP routines until the display shows the message “RESTRICTED.
Press YES to enter.
View or change the restricted parameter(s), and then EXIT from the menu.

Other manuals for BIFFI ICON3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BIFFI ICON3000 and is the answer not in the manual?

BIFFI ICON3000 Specifications

General IconGeneral
BrandBIFFI
ModelICON3000
CategoryControl Unit
LanguageEnglish

Related product manuals