EasyManua.ls Logo

Bimar DEU315 - Page 42

Bimar DEU315
155 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
flammable material.
1.1.5 Checking for presence of refrigerant. T
he
area
shall
be
checked
with
an
appropriate
refrigerant
detector
prior
to
and
during work, to ensure the technician is aware of potentially
flammable atmospheres. ensure that the leak detection
equipment being used is suitable for use with flammable
refrigerants, i.e. non-sparking, adequately sealed or intrinsically
safe.
1.1.6 Presence of fire extinguisher. if any hot work is to be
conducted on the refrigeration equipment or any
associated
parts, appropriate fire extinguishing equipment shall be available
at
hand.
Have a dry powder or CO2 fire extinguisher adjacent to the
charging area.
1.1.7 No ignition sources. No person carrying out work in
relation to a refrigeration system which involves exposing any
pipe work that contains or has contained flammable refrigerant
shall use any sources of ignition in such a manner that it may
lead to the risk of fire or explosion.
all possible ignition sources, including cigarette smoking, should
be kept sufficiently far away from the site of installation,
repairing, removing and disposal, during which flammable
refrigerant can possibly be released to the surrounding space.
Prior to work taking place, the area around the equipment is to
be surveyed to make sure that there are no flammable hazards
or ignition risks. No Smoking signs shall be displayed.
1.1.8 Ventilated area. Ensure that the area is in the open or that
it is adequately ventilated before breaking into the system or
conducting any hot work.

Related product manuals