3
Introduction
This manual is intended for the Palma RAW and Palma. The Palma RAW consists of an air circulation
heater. The Palma consists of the air circulation heater and a wet room thermostat Thermol.The
electric air circulation heater Palma and Palma RAW serves to control the
temperature of greenhouses and conservatories.
Thermo 2 (Palma Digital only) Palma
Device type Digital-Thermostat Device type Air circulation heater
Power supply 110VAC ±10%, 50/60Hz Power supply 110VAC ±10%, 50/60Hz
Max. breaking capacity
1500 W Maximum performance 1500 W
Max. switching current 16 A
Maximum power
consumption
9,0 A
Control range: ± 0 – 90 °F Control range 32 to 185 °F
Distinction rate ± 2 °F Controller tolerance: ± 41 °F
Input < 1,5 W Input < 1,5 W
Protection class II Protection class I
Protective system IP X4 Protective system IP X4
Sensor length: approx. 5ft Dimensions 11 x 8 x 12.5“
US
WARNING!
To reduce the risk of fire, electric shock, or personal injury, read
carefully and follow these instructions as well as the general
advice on safety and risks before installation. Keep this leaflet in a
safe place for future reference. If you have any doubt about the sa-
fety of the unit seek the advice of an expert. If the unit is used in a
greenhouse make sure that the electrical connections are carried
out by qualified personnel.