058-870 Table, Pain Management C-Arm, 115 VAC
058-875 Table, Pain Management C-Arm, 230 VAC
!"!
Featuring a large radiolucent area, motorized actuation of
height, lateral roll and Trendelenburg motions, the Pain
Management C-Arm Table is ideal for pain care applications.
A portable hand-held controller and optional foot-operated
controller can be positioned for convenient access from any
point around the table. The portable hand-held and optional
foot-operated controllers offer the freedom to adjust height,
lateral roll, and Trendelenburg motions from locations away
from the table, or when hands are busy with other functions.
The hand-held controller hangs on an accessory rail when
not in use.
Designed for procedures where stability, access, and pre-
cise, quiet, vibration-free positioning are essential, the Pain
Management C-Arm Table is excellent for image-guided pro-
cedures. A cantilevered low attenuation carbon fiber tabletop
accommodates portable or ceiling-suspended C-Arms. The
radiolucent area is free of cross members, allowing full fluo-
roscopic visualization and unobstructed C-Arm positioning.
Functional design provides complete access with reduced
radiation exposure to clinicians. Patient comfort and stability
are assured by two-inch thick table padding and three
adjustable straps with Velcro® hook and loop fastening. A
face cutout is provided for prone positioning.
NOTE: The Pain Management C-Arm Table tabletop is
made of carbon fiber. This material, as used in this product,
is certified to meet all the requirements of radiation perform-
ance standards of 21 CFR Subchapter J.
Figure 1. Parts and adjustment mechanisms.
1. Hand-Held Controller
2. Foot End Locking Brakes and Swivel Casters
3. Head End Caster Brake Locking Bar
! !"!
CAUTION: Refer to instruction manual before oper-
ating or servicing system.
ATTENTION: Se référer à la notice d’utilisation
avant d’utiliser l’equipement.
CAUTION: Hospital grade plug to be plugged into
a hospital grade receptacle only to achieve ground-
ing reliability.
ATTENTION: La fiche de qualité húpital ne doit Ítre
branchÈe que sur une prise de courant de qualité
hÙpital, pour une mise á la terre fiable.
CAUTION: Before transferring a patient onto or off
the table, ensure all four caster brakes are locked.
Secure the restraining straps immediately after
positioning the patient on the table.
ATTENTION: Avant le transfert du patient sur la
table ou hors de la table, síassurer que les quatre
freins des roulettes sont bloqués. Fixer les
lanières díimmobilisation dès quíon a positionné le
patient sur la table.
CAUTION: The restraining straps are not intended
to restrain an uncontrolled patient.
ATTENTION: Les laniéres díimmobilisation níont
pas pour objet líimmobilisation díun patient hors
de contrúle.

!
!
!
!
!
!
!
!