Do you have a question about the Biomet 3i Navigator and is the answer not in the manual?
Category | Dental equipment |
---|---|
Manufacturer | Biomet 3i |
Type | Navigation system |
Compatibility | Biomet 3i implants |
Application | Guided dental implant surgery |
General guidelines for surgical and restorative practitioners and laboratory technicians.
Factors to consider when evaluating a patient prior to implant surgery.
Planning implant lengths, diameters, locations, and assessing the anatomical foundation.
Overview of the BIOMET 3i Navigator System for guided surgery and its benefits.
Lists compatible implants and details the 2mm Fixation System.
Guides instruments through the surgical guide for depth stop and orientation.
Components for positioning implant analogs into a cast for laboratory work.
Components used through Master Tubes to place implants during surgery.
Used through Master Tubes to remove soft tissue for flapless surgery.
Perforate cortical plate, create pilot, and countersink osteotomy.
Guide and stop Twist Drills at predetermined depths for osteotomy preparation.
Prepare the osteotomy for implant placement with specific diameters and lengths.
Used to thread a section of the osteotomy prior to implant placement.
Holder slots to receive implant packaging for pre-mounting before placement.
Remove crestal bone for proper abutment seating after guide removal.
Standard drivers and ratchets included in the system for placing implants.
Explains the surgical plan and how it specifies instrument use and depth lines.
Key considerations before the CT scan and surgical guide fabrication.
Steps for inspecting and preparing the surgical guide and components.
Guidance on using the system during flapless surgery and advancing instruments.
Using irrigation, handling instruments, and implant mount removal.
Highlights the benefit of immediate provisionalization and component selection criteria.
Initial steps for making impressions and fabricating baseplates/occlusal rims.
Procedures for wax try-in, processing, duplication, and finishing the scanning appliance.
Process of duplicating an existing denture to create a scanning appliance.
Steps to create a master cast, articulate it, and make a vacuum-formed template.
Steps for creating a master cast, articulating, and making a vacuum-formed template for partially edentulous cases.
Measuring soft-tissue depth and selecting the correct abutment collar height.
Fabricating the provisional restoration using the master cast and template.
Procedure for placing implants using a surgical guide.
Steps for delivering the provisional restoration after surgery.
Selecting Provide Abutment collar height and post height based on measurements.
Fabricating the provisional restoration using Provide Temporary Cylinders.
Implant placement using a surgical guide as per manufacturer instructions.
Delivering the provisional restoration after implant placement.
Selecting Low Profile Abutment collar height and angulation.
Fabricating the provisional restoration using Low Profile Temporary Cylinders.
Placing implants using a surgical guide according to instructions.
Delivering the provisional restoration after surgery.
Selecting PreFormance Temporary Cylinders for contouring restorations.
Fabricating provisional restorations using PreFormance Temporary Cylinders.
Performing implant placement with a surgical guide.
Steps for delivering the provisional restoration after surgery.
Selecting Low Profile Abutments and QuickBridge components for multiple units.
Fabricating provisional restorations for multiple-unit cases.
Placing implants using a surgical guide.
Delivering the provisional restoration after surgery.