BIONEST® reactor
Aerator (air pump)
The lter of each aerator (air pump) must be cleaned periodically. According to the aerators (air
pumps) location (dusty area), a more frequent cleaning by the owner may become necessary; a
clogged lter may cause overheating or pump failure. To clean the air lter:
1. Disconnect the aerator (air pump) and BIOLARM® power supplies.
2. Remove the aerator (air pump) cover by unscrewing the screw and pulling on the cover.
3. Remove and clean the lter. If required, clean with soapy water. If cleaned with water,
make sure the lter is well rinsed under clear water and dried thoroughly before
putting it back into place.
4. Install the lter and cover making sure the seal joint is positioned correctly.
Replace previously removed screw.
5. Turn on aerator (air pump) and BIOLARM® power supplies.
Attention : Please make sure the aerator (air pump) is installed in a well ventilated room,
away from dust.